Low-intensity pulsed ultrasound increased chronic recording yield while reducing the activation of microglia surrounding electrode interface.
Neural implants hold great potential as a treatment for various neurological disorders. However, placement of these implants can damage brain tissue during insertion and evoke a foreign body response (FBR). The FBR can damage neurons, causing glial scarring and neuronal cell loss near electrode sites, which can ultimately affect electrode longevity and stability. To clear […]
See abstract details
Neural implants hold great potential as a treatment for various neurological disorders. However, placement of these implants can damage brain tissue during insertion and evoke a foreign body response (FBR). The FBR can damage neurons, causing glial scarring and neuronal cell loss near electrode sites, which can ultimately affect electrode longevity and stability. To clear the path for clinical applications, significant efforts to limit the chronic effects of insertion damage are still needed. Past work has reported that transcranial focused ultrasound promotes neurotrophic factors in cerebral disease and injury models. The current study explores the protective effects of localized low-intensity pulsed ultrasound (LIPUS) to reduce microglia reactivity and preserve electrophysiological quality in rodents following chronic electrode implantation. A reusable head-mounted LIPUS delivery system was developed and tested. Transducers were characterized in water prior to in vivo testing. To record neural activity, NeuroNexus probes were implanted at a 45°angle (A4x4-5mm-100-125-703-CM16LP) or vertically (A1x16-5mm-100-703_H16) to record stimulus evoked activity in rats (N=12, Sham=4, Vertical LIPUS=4, Slanted LIPUS=4). Subjects were treated with periodic LIPUS or Sham (Control), daily in Week 1, followed by twice weekly treatments during Weeks 2-6. LIPUS delivered in 3 x 5 min periods with 5 min of quiescence between each period. Stimulation parameters: Burst Duration: 50 ms, Repetition Rate: 2Hz, Ita: ~250-300 mW/cm2. Reactivity and neural activity were assayed with two-photon imaging and electrophysiology recordings. Ex vivo and bench tests demonstrated that ultrasound transmitted across the skull without detrimental heating or signal loss. LIPUS-treatment resulted in a lower level of probe coverage around Day 6 and remained consistently lower than Sham (two-sided Šídák’s multiple comparisons test, p=0.0187, LIPUS=7; Sham=6. Glial fibrillary acidic protein intensity, whose expression increases in response to neuroinflammation or injury, increased in the Sham compared to LIPUS-treated, 30 µm from the probe. LIPUS treatment significantly decreased average vessel diameter on day 28 (one-sided Tukey’s multiple comparison test, p=0.02). LIPUS-treated showed an improved signal-to-noise ratio at 28 days, improved single unit detection, reduced capillary diameter, and reduced microglial and astrocytic encapsulation of the probe- all critical factors for improving longer-term neural electrode viability.